Commercial Operation Date / Time: |
12 March 2013 / 16:00 hrs. |
Primary Fuel: |
Natural Gas |
Backup Fuel: |
ASL (Arabian Super Light) |
Reference Site Conditions: |
40°C Ambient Temperature; 30% Relative Humidity; 942 mbar Ambient Pressure |
Plant Design Capacity: |
1804.267 MW |
Net Dependable Capacity: |
1729.021 MW |
Plant Net Power Output: |
1755.6 MW |
Plant Heat Rate (Gross): |
7037 KJ/KWh |
Plant Heat Rate (Net): |
7232 KJ/KWh |
Gas Turbine Gross Power Output: |
157.082 MW |
Steam Turbine Gross Power Output: |
353.022 MW |
Gas Turbine Make / Model / Control: |
General Electric / 7FA.04 / Mark VIe |
Steam Turbine Make / Model: |
General Electric / D11H / Mark VIe |
Gas Turbine Generator Make / Model / Rating: |
General Electric / 7FH2 / 215 MVA, 18KV |
Steam Turbine Generator Make / Model: |
General Electric / 390H / 455 MVA, 22KV |